Slab Edge Fire Stopping

Slab edge fire stopping seals the gap between a building’s floor slabs and its external wall. Left open, that gap lets fire and smoke climb from one floor to the next behind the façade. TECL installs tested slab edge systems on new build and refurbishment projects, and records every metre we install.

Why slab edge fire stopping matters

Each floor of a building is designed as a fire compartment. The joint where the floor meets the external wall or curtain wall is one of the most common places that compartment fails. A correctly installed, tested perimeter seal keeps fire and smoke on the floor where they start, protecting escape routes above.

Siderise slab edge fire barrier with an acoustic membrane above it, between the floor slab and the façade
A Siderise slab edge fire barrier with an acoustic membrane fitted above it, sealing the joint between the floor slab and the façade.

Acoustic performance at the slab edge

The slab edge is a weak point for sound as well as fire. The joint between the floor slab and the façade gives sound a path from one floor to the next that bypasses the floor itself, known as flanking. A fire barrier on its own does little to stop it.

On façade projects we fit an acoustic membrane over the slab edge fire barrier. Siderise designs its CW-AB overlay for its CW range of curtain wall fire barriers: a 12 mm high-mass membrane on acoustic foam with a reinforced foil face. Siderise quotes about 22 to 25 dB Rw for a typical curtain wall fire barrier alone, up to 37 dB Rw with the overlay, and up to 51 dB Rw when it is combined with an acoustic void barrier (manufacturer data).

What the Building Regulations require

Fire: Approved Document B

Where a compartment floor meets an external wall, the junction must be fire-stopped to the same fire resistance as the floor, and cavities in the external wall need cavity barriers in line with each compartment floor. The slab edge barrier is what keeps each floor a separate fire compartment.

Sound: Approved Document E

Approved Document E sets sound insulation standards for floors between flats and for rooms for residential purposes, such as student accommodation and hotels. For new purpose-built flats, separating floors must achieve at least 45 dB DnT,w + Ctr for airborne sound and no more than 62 dB L’nT,w for impact sound. For flats formed by a change of use, the figures are 43 dB and 64 dB (Approved Document E, Table 1a).

These standards are measured on site across the whole construction, so sound travelling through an untreated slab edge counts against the result. For offices and other buildings outside Approved Document E, the acoustic target comes from the project specification. We work to whichever applies, and record every metre of barrier and membrane we install.

What we install

  • Slab edge and perimeter seals behind curtain walling
  • Linear joint seals between floors and external walls
  • Seals at movement joints, sized to the tested movement range
  • Remedial slab edge works in existing buildings

How we work

Our fire stopping division, led by Adam Duffield, installs only systems tested for the exact joint width, substrate and façade type on your drawings. Every length is photographed, located and signed off, so you have the evidence for building control, your O&M manual and the golden thread. We’re certified under LPS 1531, and we issue an LPCB certificate for the job.

Frequently Asked Questions

What is slab edge fire stopping?

It’s a fire-rated seal that closes the gap between the edge of a floor slab and the external wall, stopping fire and smoke passing from floor to floor.

Is slab edge fire stopping the same as a cavity barrier?

No. A slab edge seal closes the gap at the floor edge inside the building line. Cavity barriers close cavities within the wall or façade itself. Many buildings need both.

Can you fix slab edge seals in an existing building?

Yes. We survey the existing joints, then replace missing or failed seals with tested systems and record each one.

Need slab edge fire stopping? Call 0113 243 0254, email [email protected] or contact us for advice or a free quote.